Termékek
-
Dynair FC Single speed centrifugal roof fans – Horizontal discharge
Construction
- Base frame in galvanized steel sheet.
- Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997.
- Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940.
- Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
- Upper cover in ABS, with appropriate slots for motor cooling.
- Outer deflector (FCV) in ABS
Accessories
- Backdraught gravity shutter (TS)
- Silencer (GR)
- Support base for wawed roof coverings (BA)
- Inlet Protection Guard (RA)
- Service switch
- Support base/Silenced reduction (PB)
CATALOGUE
ACCESSORIES
-
Dynair FC AT – FC 2V AT Single or dpouble speed centrifugal roof fans for air temperature up to 200°C
CONSTRUCTION
- Base frame in galvanized steel sheet
- Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI EN 12499
- Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
- Upper cover in aluminium, with appropriate slots for motor cooling
- Asynchronous three-phase motor or singlephase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked,
IP 55, class F
ACCESSORIES
- Backdraught gravity shutter (TS)
- Silencer (GR)
- Counterbase (CB)
- Support base for wawed roof coverings (BA)
- Inlet Protection Guard (RA)
- Service switch
- Support base/Silenced reduction (PB)
- Flat protection guard (CCr)
CATALOGUE
-
Dynair FC 2V Double speed centrifugal roof fans – Horinzontal discharge
Construction
- Base frame in galvanized steel sheet
- Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
- Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
- Asynchronous and double polarity three-phase motor manufactured according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP55 Class F.
- Upper cover in techno-polymer, with appropriate slots for motor cooling
- Outer deflector in techno-polymer.
Accessories
- Backdraught gravity shutter (TS)
- Silencers (GR)
- Counterbase (CB)
- Support base for wawed roof coverings (BA)
- Inlet side Guard (RA)
- Service switch
- Self transformer speed regulator
- Delta/start switch
- Support base/Silenced reduction (PB)
CATALOGUE
ACCESSORIES
-
Dynair F Radial blade centrifugal fans in aluminium
Construction
- Volute casing in die cast aluminium, protected against atmospheric agent by epoxy paint. Support feet are integral part of the casing
- Single inlet, open blade, radial impeller in die cast aluminium
- Execution 5 (with impeller directly coupled to flanged motor)
- Fixed orientation RD 270°
- Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/34/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).
Accessories
- Inlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents.
CATALOGUE
-
Dynair ERM-EX Enhanced safety mixed flow fans
The ERM-EX fans are the only mixed fl ow in line series in increased safety execution “EExe“ available on the market.
The particular construction allows the installation in hazardous environment as: battery rooms, dyeing-plants, garages, etc.
Suitable to convey clean air with working temperature from -20°C to 50°C.
The ERM-EX are not suitable for regulation.Accessories
- Reduction
- Protection guard
- Fixing clamps
CATALOGUE
-
Dynair DIC-INOX Centrifugal fans in stainless steel
Construction
- Volute in stainless steel AISI304 sheet
- Single inlet forward bladed impeller (sirocco), in stainless steel AISI304
- Execution 5 (with impeller directly coupled to flanged motor)
- Standard orientation LG270°
- Motorizations: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC-INOX 100 T and M with motor shape B14, IP44, class B.
Accessories
- Inlet and outlet protection guard according to UNI 12499 norm
- Motor support in steel sheet protected against atmospheric agents by epoxy paint
CATALOGUE
ACCESSORIES
-
Dynair DIC-ATEX – DIC-INOX-ATEX Forward curved blade centrifugal fans
Construction
- Volute casing in steel sheet, protected against atmospheric agents by epoxy paint or in stainless steel AISI304 sheet
- Single inlet, single gauge, forward curved impeller (sirocco type), in galvanized steel sheet or in stainless steel AISI304
- Steel sheet inlet with epoxy finish or inox inlet on models IIB. Brass inlet on models with execution IIC
- Execution 5 (with impeller directly coupled to flanged motor)
- Motor separated from the conveyed airflow
- Standard orientation LG270°
- Inlet connector supplied (disassembled)
- DIC-ATX and DIC-ATX INOX asynchronous three- phase motors or single-phase according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55, class F, B35 shape. Suitable to S1 service (continuous working at constant load)
Accessories
- Motor support in steel or steel sheet
- Inlet and outlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents
CATALOGUE
-
Dynair DIC Forward curved blade centrifugal fans
Construction
- Volute casing in steel sheet, protected againstatmospheric agents by epoxy paint
- Single inlet, single width, forward curved impeller (sirocco type), in galvanized steel sheet
- Execution 5 (with impeller directly coupled to flanged motor)
- Standard orientation LG 270°
- Motorization: Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC 100 T and M with motor shape B14, IP44, class B. All motors suitable to S1 service (continuous working at constant load).
Accessories
- Inlet and outlet protection guard according to UNI 10615 rules and protected against atmospheric agents
- Motor support in steel sheet epoxy painted.
CATALOGUE
ACCESSORIES
-
Dynair DIC AT Forward curved blade centrifugal fans for air temperature up to +150°C
Construction
- Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet, single width forward curved impeller (sirocco type), in galvanized steel sheet
- Execution 5 (with impeller directly coupled to flanged motor)
- Standard orientation LG270°
- Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC 100 T and M with motor shape B14, IP44, class B.
Accessories
- Inlet and outlet protection guard according to UNI 12499 rules and protected against atmospheric agents
- Motor support in steel sheet epoxy painted.
CATALOGUE
-
Dynair DA-T Direct drive double inlet fans without motor
The fans of the DA-T series are suitable in plants of ventilation and air conditioning, filtering and heating. They can only handle clean air with temperature range from -20°C to +80°C and to work they require a containing structure (plenum).
The fans must be used within the limits shown in the relevant table.They can only handle clean air up to the maximum temperature of 40°C and to work they require a containing structure (plenum). The fans must be used within the limits shown in the relevant table.
Upon request:
- “CUBIK” version.
CATALOGUE
ACCESSORIES
-
Dynair DA Direct drive double inlet fans
Construction
- Volute in galvanized steel sheet
- Direct drive double inlet forward curved wheel
- Single-phase and three-phase motor (only 12/9 and 12/12), IP20, class F. Thermal protection in single-phase versions. Particularly suitable for speed regulation (using the suitable speed regulators shown in this catalogue)
Accessories
- Outlet flange
- Fixing feet
CATALOGUE
ACCESSORIES
-
Dynair CCZ Compact and high efficiency ducted axial fans
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- High quality aerofoil profiled impellers in mineral fibres reinforced technopolymer (310 to 400) and diecast aluminum alloy (450 to 560). Blades are directly fixed to the motor external rotor
- Execution 5 (with impeller directly coupled to the motor) and airflow from motor to impeller
- External rotor motors with built-in thermal protection, double speed three-phase and single- phase, speed adjustable. All motors with mounted connection box
Accessories
- Flat protection guard (CCr)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts.
CATALOGUE
ACCESSORIES