Termékek

  • Dynair AXC – LINE METAL Round duct centrifugal in-line fans

    Construction

    • Casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Single-phase electric ball-bearing motor with non-self resetting thermal cut-out, particularly suitable for speed regulation
    • Backward curved centrifugal impeller with high efficiency and low noise level. Statically and dynamically balanced according to ISO 1940
    • Down stream guide vanes, for improved efficiency
    • External electric connections enclosed in a terminal box in self-extinguishing technopolymer, with IP54 protection
    • Comply with EN 60335-2-80, B.T. 2006/95/ CE, EMC 2004/108/CE

    Accessories

    • Speed regulators
    • Back-draught shutters
    • Protection guard
    • Collars for fixing to the duct
    • Silencers

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair AxB Super-silent acoustic cabinet fans

    Construction

    • Casing in galvanized steel sheet with fixing flanges of standardized dimensions
    • Single-phase and three-phase electric external rotor motor, IP44, class B/F, with internal thermal protection, suitable for speed control (using the suitable speed regulators shown in this catalogue)
    • Backward curved impeller for models 4×2, 5×2,5 and 5×3, forward curved impeller for models 6×3, 6×35 and 7×4
    • External electric connection box, in a self-extinguishing techno-polymeric box, resistant to atmospheric agents with IP55 protection.

    Accessories

    • Speed regulators
    • Silencers
    • Flexible connections

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair Ancillary control systems

    Control panels – CO and gas sensors

    CE 408 – Panel for small systems – from 4 to 8 CO sensors

    • Equipped with 4 inputs and 5 relays expandable upto 8 inputs and 9 relays
    • IP 40

    CE 424 – Panel for medium size systems – from 4 to 24 CO sensors

    • Equipped with 4 inputs and 5 relays expandable up to 24 inputs and 25 relays
    • IP 40

    CE 700 – Panel for large systems up to 200 sensors

    • Equipped with 16 inputs expandable up to 184 for a total of 200 CO sensors
    • Wall or rack versions
    • IP 40

    Industrial gas detectors (single or double gas):
    Replaceable catalytic, electrochemical, pellistor cartridge.
    Suitable for CO, petrol vapours and other gases according to the reference Norm.
    IP65

    CATALOGUE

    Quick View
  • Dynair AL-ATEX Forward curved blade centrifugal fans

    Construction

    • Volute casing in folded steel sheet, protected against atmospheric agent by epoxy paint
    • Single inlet, single width, forward curved impeller (sirocco type), manufactured in galvanized steel sheet from type 200 to 315 and in steel sheet with welded blades epoxy painted from type 355 to 450
    • Brass inlet on models gauge execution IIC and steel sheet with epoxy finish on models IIB
    • Execution 4 (with impeller directly coupled to motor)
    • Standard orientation LG 270°

    MOTOR

    • Asynchronous three-phase motors or singlephase according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/CE, LVD 2006/95/ CE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55/IP 65, class F. Suitable to S1 service (continuous working at constant load).

    Accessories

    • Inlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents
    • Round inlet cone, in steel sheet epoxy coated

    CATALOGUE

    Quick View
  • Dynair AL Forward curved blade centrifugal fans

    Construction

    • Volute casing in folded steel sheet, protected against atmospheric agent by epoxy paint
    • Single inlet, single width, forward curved impeller (sirocco type), manufactured in galvanized steel sheet from type 200 to 315 and in steel sheet with welded blades epoxy painted from type 355 to 450
    • Execution 4 (with impeller directly coupled to motor with feet)
    • Standard orientation LG 270°

    Motorizations:

    • AL: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/uE, LVD 2014/35/UE, CE marked, IP 55, class F
    • AL-ATX: asynchronous three-phase motors or single-phase II2G,II2D,II2GD according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification, CE marked, IP55/IP 65, class F
    • All motors suitable to S1 service (continuous working at constant load)

    Accessories

    • Inlet protection guard manufactured according to UNI 10615 norm and protected against the atmospheric agents
    • Round inlet cone, in steel sheet epoxy coated.

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair AC-A and AC-B Ring axial fans

    The fans of the AC series are suitable for the ventilation in residential, commercial and industrial buildings in which are requested relevant air deliveries without canalization.

    They are also suitable as OEM in a wide variety of applications. With the addition of a suitable wall mounting square frame adaptor, the AC fans (from size 800 to 1250) can be converted in a wall mounted fan (like QC range).
    The series includes 2 versions: AC/A and AC/B, with impeller diameter from 300 a 1250 mm and different motor polarity. The AC-A model has a shaped cone in the inlet side, while for the AC/B the shaped cone is present also on the outlet. They are designed for clean air in the temperature range -10°C 50°C.
    The optimized inlet cone reduces noise level and increases the efficiency.

    Upon request:

    • Impeller with airfoil blades in die-cast aluminium alloy
    • Airflow from impeller to motor (only AC/B)

    CATALOGUE

    ACCESSORIES

    Quick View