Backward curved blade centrifugal fans for clean air
-
PV-L/AT-INOX Backward curved blade centrifugal fans for dusty air
Construction
- Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
- Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted
- For high rotational speed, versions in class 3 are foreseen
- For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, designed for easy lubrication
- Pulleys, belts and motor support. Belt protection guard
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)
Accessories
- Condensation drain hole (TS)
- Inspection door (PI)
- Inlet counter-flange (CFA)
- Outlet counter-flange (CFP)
- Inlet protection guard (RA)
- Outlet protection guard (RP)
- Inlet flexible connector (GA)
- Outlet flexible connector (GP)
- Inlet vane control
- Outlet setting shutter
- Anti-vibration mounts
CATALOGUE
-
PR-L/AT-INOX Backward curved blade centrifugal fans for clean or slightly dusty air
Construction
- Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
- Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
- For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)
Accessories
- Condensation drain hole (TS)
- Inspection door (PI)
- Inlet counter-flange (CFA)
- Outlet counter-flange (CFP)
- Inlet protection guard (RA)
- Outlet protection guard (RP)
- Inlet flexible connector (GA)
- Outlet flexible connector (GP)
- Inlet vane control
- Outlet setting shutter
- Anti-vibration mounts
CATALOGUE
-
Dynair PV-L Backward curved blade centrifugal fans for dusty air
Construction
- Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
- Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted
- For high rotational speed, versions in class 3 are foreseen
- For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication
- Pulleys, belts and motor support. Belt protection guard
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).
Accessories
- Condensation drain hole (TS)
- Inspection door (PI)
- Inlet counter-flange (CFA)
- Outlet counter-flange (CFP)
- Inlet protection guard (RA)
- Outlet protection guard (RP)
- Inlet flexible connector (GA)
- Outlet flexible connector (GP)
- Inlet vane control
- Outlet setting shutter
- Anti-vibration mounts
CATALOGUE
-
Dynair PS-L/AT-INOX Backward curved blade centrifugal fans for dusty air
Construction
- Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
- Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
- For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)
Accessories
- Condensation drain hole (TS)
- Inspection door (PI)
- Inlet counter-flange (CFA)
- Outlet counter-flange (CFP)
- Inlet protection guard (RA)
- Outlet protection guard (RP)
- Inlet flexible connector (GA)
- Outlet flexible connector (GP)
- Inlet vane control
- Outlet setting shutter
- Anti-vibration mounts
CATALOGUE
-
Dynair PR-Q AT Backward curved blade centrifugal fans for clean air or slightly dusty air with t from 100 to 200°C
Construction
- Volute casing with quadrangular frame, manufactured in galvanized steel sheet and protected against atmospheric agents with epoxy finish
- Single inlet, backward curved wheel with high efficiency, manufactured in galvanized steel sheet and die-cast aluminium hub
- Execution 5 (impeller directly coupled to fl anged motor), rotation RD
- Asynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/30/CE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)
Accessories
- Inlet and outlet protection guard manufactured according to UNI 12499 norm and protected against atmospheric agents
- Inlet/outlet flexible connectors
- Antivibration supports
- Inlet/outlet counterflange
- Self transformer or inverters speed controllers
CATALOGUE
ACCESSORIES