Centrifugal roof fans

  • Dynair REV Centrifugal roof fans with external rotor motor – Vertical discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet (mod. 200 in plastic), with high efficiency and low noise level
    • Outer deflector in ABS
    • External rotor motor, three-phase or single phase, IP 44/B 200-250, IP 44/F 310-400, tropycalized with integral thermal protection

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencers (GR)
    • Counter base to be walled up (CB)
    • Support base for corrugated roof coverings (BA)
    • Inlet side Guard (RA)
    • Service switch
    • Speed regulator
    • Delta/start switch
    • Support base/Silenced reduction (PB). Not available for size 200

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair REA Centrifugal roof fans with external rotor motor – Horizontal discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet (mod. 200 in plastic), with high efficiency and low noise level
    • Upper cover in aluminium
    • External rotor motor, three-phase or single phase, IP 44/B 200-250, IP 44/F 310-400, tropycalized with integral thermal protection.

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencers (GR)
    • Counter base to be walled up (CB)
    • Support base for corrugated roof coverings (BA)
    • Inlet side Guard (RA)
    • Service switch
    • Speed regulator
    • Delta/start switch
    • Support base/Silenced reduction (PB). Not available for size 200

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FCV Single speed centrifugal roof fans – Vertical discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F
    • Upper cover in ABS, with appropriate slots for motor cooling
    • Outer deflector in ABS

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FCV 2V Double speed centrifugal roof fans – Vertical discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
    • Upper cover in ABS, with appropriate slots for motor cooling
    • Outer deflector in ABS

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FC Single speed centrifugal roof fans – Horizontal discharge

    Construction

    • Base frame in galvanized steel sheet.
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997.
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940.
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
    • Upper cover in ABS, with appropriate slots for motor cooling.
    • Outer deflector (FCV) in ABS

     

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FC 2V Double speed centrifugal roof fans – Horinzontal discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous and double polarity three-phase motor manufactured according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP55 Class F.
    • Upper cover in techno-polymer, with appropriate slots for motor cooling
    • Outer deflector   in techno-polymer.

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencers (GR)
    • Counterbase (CB)
    • Support base for wawed roof coverings (BA)
    • Inlet side Guard (RA)
    • Service switch
    • Self transformer speed regulator
    • Delta/start switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View