Centrifugal box fans and double inlet belt driven fans
-
Dynair Box-CA Active carbon filtering units
Construction
- Frame in extruded aluminium profi les and removable double skin panels in galvanized steel sheet
- Lining of the plenum with self-extinguishing techno-polymer material
- Double inlet centrifugal fan with forward curved blades, driven by trapezoidal belts and adjustable pulleys. Fan and motor supported by single base frame and isolated from the main structure by anti-vibration mounts and flexible joint on the outlet
- Filtering battery composed by wavy polyester pre-filter (class G3), pocket filter (class F7) and activated charcoal filter in cartridges
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable for S1 service (continuous working at constant load)
Accessories
- Weatherproof cover
CATALOGUE
-
Dynair Box-T Belt driven double inlet box fans
Construction
- Frame in extruded aluminium profiles and removable panels in galvanized steel sheet
- Plenum lining of the with self-extinguishing techno-polymer material
- Double inlet centrifugal fan with forward curved blades, driven by trapezoidal belts and adjustable pulleys. Fan and motor supported by single base frame and isolated from the main structure by anti-vibration mounts and flexible joint on the outlet
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F. Suitable for S1 service (continuous working at constant load).
Accessories
- Weatherproof protection cover
- Support feet
- Outlet terminal with guard
- Setting shutter
- Setting shutter with filtering section (standard version with filter in polyester with efficiency 90.1%, class EU4).
CATALOGUE
-
Dynair DA-T Direct drive double inlet fans without motor
The fans of the DA-T series are suitable in plants of ventilation and air conditioning, filtering and heating. They can only handle clean air with temperature range from -20°C to +80°C and to work they require a containing structure (plenum).
The fans must be used within the limits shown in the relevant table.They can only handle clean air up to the maximum temperature of 40°C and to work they require a containing structure (plenum). The fans must be used within the limits shown in the relevant table.
Upon request:
- “CUBIK” version.
CATALOGUE
ACCESSORIES
A termék már hozzá lett adva! View Wishlist