  • Dynair MULTIBOX Centralized single flow extract ventilation

    Construction

    • Casing in galvanised steel sheet.
    • Backward blade impeller for high efficiency and low noise level.
    • Easy access to motor and impeller for inspection.
    • Compliance with EN 60335-2-80, B.T. 2014/35/UE, EMC 2014/30/UE
    • IPX4

    Accessories

    • RLS 1 WR Remote control for the manual selection of the ventilation level (min/Intermediate/high). Suitable for Microbox EC.
    • RLS 3V Remote control for the manual selection of the ventilation level (min/Intermediate/high) and On/Off switch. Suitable for Microvox 3V AC.

    CATALOGUE

    Quick View
  • Dynair PQ-L Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1–9–12: mono-block support in cast iron with ball bearings, designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard.
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PQ-L/INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PR-L Backward curved blade centrifugal fans for clean or slightly dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PR-L/INOX Backward curved blade centrifugal fans for clean or slightly dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PR-Q AT Backward curved blade centrifugal fans for clean air or slightly dusty air with t from 100 to 200°C

    Construction

    • Volute casing with quadrangular frame, manufactured in galvanized steel sheet and protected against atmospheric agents with epoxy finish
    • Single inlet, backward curved wheel with high efficiency, manufactured in galvanized steel sheet and die-cast aluminium hub
    • Execution 5 (impeller directly coupled to fl anged motor), rotation RD
    • Asynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/30/CE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Inlet and outlet protection guard manufactured according to UNI 12499 norm and protected against atmospheric agents
    • Inlet/outlet flexible connectors
    • Antivibration supports
    • Inlet/outlet counterflange
    • Self transformer or inverters speed controllers

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair PS-L Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1–9–12: mono-block support in cast iron with ball bearings, designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PS-L/AT-INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PS-L/INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PV-L Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted
    • For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication
    • Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PV-L/INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted
    • For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication
    • Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair QCL Compact and high efficiency axial fan

    The fans of the QCL series are suitable for the ventilation, with wall or panel, in residential, commercial and industrial buildings, where reduced dimensions or adjustable performances
    are required.

    The series consists of 10 models with impeller diameter from 200 to 710 mm.
    They are designed for clean air in the temperature range -25°C / +60°C.
    The optimized inlet cone along with the bionic profile of the blades reduce noise level and increase the aeraulic and energetic efficiency according to the regulation EU 327/2011.

    Upon request:

    • Reverse airflow versions.

    CATALOGUE

    ACCESSORIES

    Quick View