ErP Directive compliant fans
-
Dynair REC SanAir Decentralized HRU
The series is available in 3 models:
REC SanAir WALL
Installation on all kind of perimetric wall.
Unique model for horizontal or vertical installation.
Easy installation: 2 holes of ø 100 mm are sufficient.REC SanAir IN WALL
Installation on any kind of perimetrical wall.
Built-in horizontal or vertical installation.REC SanAir WINDOW
Installation on all kind of window frame with dimensions
up to 180 mm of width and 3000 mm
of length.CATALOGUE
-
Dynair REC SMART Decentralized HRU
Construction
- High energy saving thanks to EC motors
- Integrate by-pass and antifreeze functions.
- Provided with 3 filters: the air is filtered in both flows before entering the heat exchanger.
- Easy maintenance and cleaning: filters and heat exchanger are removable and washable.
- Comply with EN 60335-2-80, B.T. 2014/35/UE, EMC 2014/30/UE.
Accessories
- Remote Speed control (min-max) and on/off switch.
CATALOGUE
-
Dynair REC SMART+ Decentralized HRU with Touch Panel or remote controller
Construction
- High energy saving thanks to EC motors
- Integrate by-pass and antifreeze functions.
- Provided with 3 filters: the air is filtered in both flows before entering the heat exchanger.
- Easy maintenance and cleaning: filters and heat exchanger are removable and washable.
- Comply with EN 60335-2-80, B.T. 2014/35/UE, EMC 2014/30/UE.
CATALOGUE
-
Dynair REV Centrifugal roof fans with external rotor motor – Vertical discharge
Construction
- Base frame in galvanized steel sheet
- Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
- Backward curved wheel in galvanized steel sheet (mod. 200 in plastic), with high efficiency and low noise level
- Outer deflector in ABS
- External rotor motor, three-phase or single phase, IP 44/B 200-250, IP 44/F 310-400, tropycalized with integral thermal protection
Accessories
- Backdraught gravity shutter (TS)
- Silencers (GR)
- Counter base to be walled up (CB)
- Support base for corrugated roof coverings (BA)
- Inlet side Guard (RA)
- Service switch
- Speed regulator
- Delta/start switch
- Support base/Silenced reduction (PB). Not available for size 200
CATALOGUE
ACCESSORIES
-
Dynair S-Cube Backward curved centrifugal box fans
Construction
- Frame in extruded aluminium profiles and removable double skin panels in galvanized steel sheet; all this brings to an excellent aesthetic impact
- Acoustic lining of the panels in self-extinguishing techno-polymer
- Backward curved impeller directly coupled to the motor
- B3 Motor fitted using suitable reinforced support seat
- Support brackets with holes suitable for lifting and easy installation
- Motor equipment:
- Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F
- All suitable to S1 service (continuous working at constant load)
Accessories
- Weatherproof cover
- Rainproof discharge outlet with guard
- Anti-vibration supports
- Floor support feet
- Square/Round outlet connector
CATALOGUE
ACCESSORIES
-
Dynair TACC Compact axial roof fans
Construction
- Fixing base in galvanized steel sheet
- Casing in steel sheet, epoxy coated
- Axial impeller with aerofoil profile blades in glass reinforce polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
- Weatherproof upper cover in fiberglass
- Air flow from motor to impeller
- Protection guard on outlet side, in steel rod, manufactured according to norms UNI 10615 and weatherproof
- Asynchronous three-phase or single-phase motor according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F
- All suitable to S1 service (continuous working at constant load)
Accessories
- Inlet gravity shutter. (SA)
- Counter-base to be walled up (CB)
- Support base and Reduction (BA and RD)
- Support base/Silenced reduction (PB)
- Motor side protection grid (CCrc)
CATALOGUE
-
Dynair ZOO Belt driven axial fans
Construction
- Belt-driven fans
- Airflow outside the motor
- Housing manufactured in galvanized steel sheet
- Impeller blades made of stainless steel AISI 304 with aluminium hub
- Asynchronous three phase motor ball bearing motors 230/400V – 50Hz suitable for continuous running
- Protection grade IP54, Class F
CATALOGUE
-
PR-L/AT-INOX Backward curved blade centrifugal fans for clean or slightly dusty air
Construction
- Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
- Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
- For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)
Accessories
- Condensation drain hole (TS)
- Inspection door (PI)
- Inlet counter-flange (CFA)
- Outlet counter-flange (CFP)
- Inlet protection guard (RA)
- Outlet protection guard (RP)
- Inlet flexible connector (GA)
- Outlet flexible connector (GP)
- Inlet vane control
- Outlet setting shutter
- Anti-vibration mounts
CATALOGUE
-
PV-L/AT-INOX Backward curved blade centrifugal fans for dusty air
Construction
- Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
- Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted
- For high rotational speed, versions in class 3 are foreseen
- For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, designed for easy lubrication
- Pulleys, belts and motor support. Belt protection guard
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)
Accessories
- Condensation drain hole (TS)
- Inspection door (PI)
- Inlet counter-flange (CFA)
- Outlet counter-flange (CFP)
- Inlet protection guard (RA)
- Outlet protection guard (RP)
- Inlet flexible connector (GA)
- Outlet flexible connector (GP)
- Inlet vane control
- Outlet setting shutter
- Anti-vibration mounts
CATALOGUE