ErP Directive compliant fans

  • Dynair FCV 2V Double speed centrifugal roof fans – Vertical discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
    • Upper cover in ABS, with appropriate slots for motor cooling
    • Outer deflector in ABS

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FC Single speed centrifugal roof fans – Horizontal discharge

    Construction

    • Base frame in galvanized steel sheet.
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997.
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940.
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
    • Upper cover in ABS, with appropriate slots for motor cooling.
    • Outer deflector (FCV) in ABS

     

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FC AT – FC 2V AT Single or dpouble speed centrifugal roof fans for air temperature up to 200°C

    CONSTRUCTION

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI EN 12499
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Upper cover in aluminium, with appropriate slots for motor cooling
    • Asynchronous three-phase motor or singlephase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked,
      IP 55, class F

    ACCESSORIES

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Counterbase (CB)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)
    • Flat protection guard (CCr)

    CATALOGUE

    Quick View
  • Dynair FC 2V Double speed centrifugal roof fans – Horinzontal discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous and double polarity three-phase motor manufactured according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP55 Class F.
    • Upper cover in techno-polymer, with appropriate slots for motor cooling
    • Outer deflector   in techno-polymer.

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencers (GR)
    • Counterbase (CB)
    • Support base for wawed roof coverings (BA)
    • Inlet side Guard (RA)
    • Service switch
    • Self transformer speed regulator
    • Delta/start switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair F Radial blade centrifugal fans in aluminium

    Construction

    • Volute casing in die cast aluminium, protected against atmospheric agent by epoxy paint. Support feet are integral part of the casing
    • Single inlet, open blade, radial impeller in die cast aluminium
    • Execution 5 (with impeller directly coupled to flanged motor)
    • Fixed orientation RD 270°
    • Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/34/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).

    Accessories

    • Inlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents.

    CATALOGUE

    Quick View
  • Dynair DIC-INOX Centrifugal fans in stainless steel

    Construction

    • Volute in stainless steel AISI304 sheet
    • Single inlet forward bladed impeller (sirocco), in stainless steel AISI304
    • Execution 5 (with impeller directly coupled to flanged motor)
    • Standard orientation LG270°
    • Motorizations: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC-INOX 100 T and M with motor shape B14, IP44, class B.

    Accessories

    • Inlet and outlet protection guard according to UNI 12499 norm
    • Motor support in steel sheet protected against atmospheric agents by epoxy paint

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair DIC Forward curved blade centrifugal fans

    Construction

    • Volute casing in steel sheet, protected againstatmospheric agents by epoxy paint
    • Single inlet, single width, forward curved impeller (sirocco type), in galvanized steel sheet
    • Execution 5 (with impeller directly coupled to flanged motor)
    • Standard orientation LG 270°
    • Motorization: Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC 100 T and M with motor shape B14, IP44, class B. All motors suitable to S1 service (continuous working at constant load).

    Accessories

    • Inlet and outlet protection guard according to UNI 10615 rules and protected against atmospheric agents
    • Motor support in steel sheet epoxy painted.

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair DIC AT Forward curved blade centrifugal fans for air temperature up to +150°C

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet, single width forward curved impeller (sirocco type), in galvanized steel sheet
    • Execution 5 (with impeller directly coupled to flanged motor)
    • Standard orientation LG270°
    • Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC 100 T and M with motor shape B14, IP44, class B.

    Accessories

    • Inlet and outlet protection guard according to UNI 12499 rules and protected against atmospheric agents
    • Motor support in steel sheet epoxy painted.

    CATALOGUE

    Quick View
  • Dynair DA Direct drive double inlet fans

    Construction

    • Volute in galvanized steel sheet
    • Direct drive double inlet forward curved wheel
    • Single-phase and three-phase motor (only 12/9 and 12/12), IP20, class F. Thermal protection in single-phase versions. Particularly suitable for speed regulation (using the suitable speed regulators shown in this catalogue)

    Accessories

    • Outlet flange
    • Fixing feet

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair CCZ Compact and high efficiency ducted axial fans

    Construction

    • Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
    • High quality aerofoil profiled impellers in mineral fibres reinforced technopolymer (310 to 400) and diecast aluminum alloy (450 to 560). Blades are directly fixed to the motor external rotor
    • Execution 5 (with impeller directly coupled to the motor) and airflow from motor to impeller
    • External rotor motors with built-in thermal protection, double speed three-phase and single- phase, speed adjustable. All motors with mounted connection box

    Accessories

    • Flat protection guard (CCr)
    • Flexible connectors (CCga)
    • Support feet (CCst)
    • Inlet/outlet bell mouth (CCbo)
    • Silencers, with and without pod, in three lengths (CCsa and CCsb)
    • Counter flange (Ccf)
    • Counter flange with collar (CCfc)
    • Anti-vibration mounts.

    CATALOGUE

    ACCESSORIES

    View Wishlist
    Quick View
  • Dynair CCP Portable duct axial fans

    Construction

    • Casing in steel sheet and support stand in tubular metal, protected against the atmospheric agents with epoxy paint. Side hand-wheels for the orientation of the throw
    • Protection guards in inlet and outlet manufactured according to rules UNI 12499
    • Aerofoil profi le impeller with blades in mineral fibres reinforced technopolymer (models 310 to 400) and die cast aluminium alloy (models 450 and 560)
    • Execution 5 (with impeller direct coupled on the shaft end) and airflow from motor to impeller
    • External rotor motors with built in thermal protection, double speed three-phase and single phase speed-adjustable, all motors with connection box.

    CATALOGUE

    Quick View
  • Dynair CCB Bifurcated ducted axial fans

    Construction

    • Stainless steel AISI 304 casing, with airtight motor housing, with fixing flanges manufactured according to ISO 13351
    • High performance axial impeller with aerofoil profile blades and hub in diecast aluminium, balanced according ISO 1940. Variable pitch angle
    • Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motorAsynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/34/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable to S1 service (continuous working at constant load).

    Accessories

    • Flat protection guard (CCr)
    • Flexible connectors (CCga)
    • Support feet (CCst)
    • Inlet/outlet bell mouth (CCbo)
    • Silencers, with and without pod, in three lengths (CCsa and CCsb)
    • Counter flange (Ccf)
    • Counter flange with collar (CCfc)
    • Anti-vibration mounts.

    CATALOGUE

    ACCESSORIES

    Quick View