ErP Directive compliant fans

  • Dynair PQ-L/INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair TACC Compact axial roof fans

    Construction

    • Fixing base in galvanized steel sheet
    • Casing in steel sheet, epoxy coated
    • Axial impeller with aerofoil profile blades in glass reinforce polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
    • Weatherproof upper cover in fiberglass
    • Air flow from motor to impeller
    • Protection guard on outlet side, in steel rod, manufactured according to norms UNI 10615 and weatherproof
    • Asynchronous three-phase or single-phase motor according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F
    • All suitable to S1 service (continuous working at constant load)

    Accessories

    • Inlet gravity shutter. (SA)
    • Counter-base to be walled up (CB)
    • Support base and Reduction (BA and RD)
    • Support base/Silenced reduction (PB)
    • Motor side protection grid (CCrc)

    CATALOGUE

    Quick View
  • Dynair S-Cube Backward curved centrifugal box fans

    Construction

    • Frame in extruded aluminium profiles and removable double skin panels in galvanized steel sheet; all this brings to an excellent aesthetic impact
    • Acoustic lining of the panels in self-extinguishing techno-polymer
    • Backward curved impeller directly coupled to the motor
    • B3 Motor fitted using suitable reinforced support seat
    • Support brackets with holes suitable for lifting and easy installation
    • Motor equipment:
      • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F
      • All suitable to S1 service (continuous working at constant load)

    Accessories

    • Weatherproof cover
    • Rainproof discharge outlet with guard
    • Anti-vibration supports
    • Floor support feet
    • Square/Round outlet connector

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair Box-D Direct drive double inlet box fans

    Construction

    • Frame in extruded aluminium profile; removable panels in galvanized steel sheet; all this brings to an excellent aesthetic impact. Weatherproof cover in galvanized steel sheet
    • The blower is fitted using suitable support feet and is completely isolated from the casing by anti-vibration mounts and gaskets
    • Acoustic lining in self-extinguishing technopolymer
    • Double inlet blower, forward curved, with direct drive built-in asynchronous motor, singlephase or three-phase, IP20, class F, particularly suitable for speed regulation (using the suitable speed regulators shown in this catalogue)
    • Weatherproof upper cover with suitable holes for lifting hooks

    Accessories

    • Rainproof outlet with guard
    • Support feet
    • Filtering section (standard version with filter in polyester with efficiency 90.1%, class EU4).

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair Mini-Box Slim-line acoustic cabinet fans

    Construction

    • Casing in galvanized steel sheet, lined with acoustic insulation (thickness 10 mm).
    • Single-phase electric motor, IP44, class F, with thermal protection, suitable for speed control.
    • Fitting bracket
    • Backward curved impeller with high effi ciency and low noise level.
    • Outer terminal box IP55.

    Accessories

    • Electric duct heaters BE.
    • Backdraught shutters.
    • Duct clamps.
    • Protection guards

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair CCB Bifurcated ducted axial fans

    Construction

    • Stainless steel AISI 304 casing, with airtight motor housing, with fixing flanges manufactured according to ISO 13351
    • High performance axial impeller with aerofoil profile blades and hub in diecast aluminium, balanced according ISO 1940. Variable pitch angle
    • Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motorAsynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/34/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable to S1 service (continuous working at constant load).

    Accessories

    • Flat protection guard (CCr)
    • Flexible connectors (CCga)
    • Support feet (CCst)
    • Inlet/outlet bell mouth (CCbo)
    • Silencers, with and without pod, in three lengths (CCsa and CCsb)
    • Counter flange (Ccf)
    • Counter flange with collar (CCfc)
    • Anti-vibration mounts.

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair DIC-INOX Centrifugal fans in stainless steel

    Construction

    • Volute in stainless steel AISI304 sheet
    • Single inlet forward bladed impeller (sirocco), in stainless steel AISI304
    • Execution 5 (with impeller directly coupled to flanged motor)
    • Standard orientation LG270°
    • Motorizations: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC-INOX 100 T and M with motor shape B14, IP44, class B.

    Accessories

    • Inlet and outlet protection guard according to UNI 12499 norm
    • Motor support in steel sheet protected against atmospheric agents by epoxy paint

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair PR-L/INOX Backward curved blade centrifugal fans for clean or slightly dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PS-L/INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PV-L/INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted
    • For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication
    • Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair DA Direct drive double inlet fans

    Construction

    • Volute in galvanized steel sheet
    • Direct drive double inlet forward curved wheel
    • Single-phase and three-phase motor (only 12/9 and 12/12), IP20, class F. Thermal protection in single-phase versions. Particularly suitable for speed regulation (using the suitable speed regulators shown in this catalogue)

    Accessories

    • Outlet flange
    • Fixing feet

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair Box-CA Active carbon filtering units

    Construction

    • Frame in extruded aluminium profi les and removable double skin panels in galvanized steel sheet
    • Lining of the plenum with self-extinguishing techno-polymer material
    • Double inlet centrifugal fan with forward curved blades, driven by trapezoidal belts and adjustable pulleys. Fan and motor supported by single base frame and isolated from the main structure by anti-vibration mounts and flexible joint on the outlet
    • Filtering battery composed by wavy polyester pre-filter (class G3), pocket filter (class F7) and activated charcoal filter in cartridges
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable for S1 service (continuous working at constant load)

    Accessories

    • Weatherproof cover

    CATALOGUE

    Quick View