Termékek

  • Dynair FC Single speed centrifugal roof fans – Horizontal discharge

    Construction

    • Base frame in galvanized steel sheet.
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997.
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940.
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
    • Upper cover in ABS, with appropriate slots for motor cooling.
    • Outer deflector (FCV) in ABS

     

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair REC Pro 75 High efficiency HRU

    Construction

    • The casing is made with double skin panels, with 25mm thick rockwool insulation with ­ re reaction class A2S1d0; external panels are in prepainted steel, internal panels in galvanized steel
    • Integrated by-pass system with actuator, for free-cooling operations
    • Access to fans and lters sections is ensured by doors with hinges and locking devices; additional access is given to the ­ lters thanks to lift-o panels
    • The units are complete with an electronic control device for the setting of the ventilation and temperature, monitoring of the status of the ­ lters, week programming, defrost management and anti-freeze device for the additional water coil module

    Accessories

    A wide range of accessories is available: consult the catalogue.

    CATALOGUE

    Quick View
  • Dynair QCL Compact and high efficiency axial fan

    The fans of the QCL series are suitable for the ventilation, with wall or panel, in residential, commercial and industrial buildings, where reduced dimensions or adjustable performances
    are required.

    The series consists of 10 models with impeller diameter from 200 to 710 mm.
    They are designed for clean air in the temperature range -25°C / +60°C.
    The optimized inlet cone along with the bionic profile of the blades reduce noise level and increase the aeraulic and energetic efficiency according to the regulation EU 327/2011.

    Upon request:

    • Reverse airflow versions.

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair ERM-EX Enhanced safety mixed flow fans

    The ERM-EX fans are the only mixed fl ow in line series in increased safety execution “EExe“ available on the market.

    The particular construction allows the installation in hazardous environment as: battery rooms, dyeing-plants, garages, etc.
    Suitable to convey clean air with working temperature from -20°C to 50°C.
    The ERM-EX are not suitable for regulation.

    Accessories

    • Reduction
    • Protection guard
    • Fixing clamps

    CATALOGUE

    Quick View
  • DYNAIR PR-AC ATEX Centrifugal fans in plastic material

    Construction

    • Volute in polyethylene
    • Single inlet impeller, in Polypropylene, with backward curved blades and aluminium hub (protected from the fluid)
    • Motor support in epoxy painted steel sheet
    • Asynchronous three-phase or single-phase ATEX motors for explosive atmospheres category G group II thermal class T4 protection Exd according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, B3 or B5 shape. Suitable to a S1 service (continuous working to constant load)

    Accessories

    • Inlet protection guard according to UNI 10615
    • Anti-vibration joint in PVC for inlet and outlet sides
    • Gravity shutter
    • Manual setting shutter

    CATALOGUE

    View Wishlist
    Quick View
  • Dynair PV-L ATEX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint. Connection flanges ISO 6580/EUROVENT 1-2
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • Aerodynamically shaped inlet cone
    • Execution 4 directly coupled and executions 1-9-12 with mono-block support in cast iron with ball bearings, designed for an ideal alignment of the ball bearings and an easy lubrication. Pulleys, belts and motor support suitable for the regulation of the belts tension. Belt protection guard according to EN12499
    • Asynchronous three-phase ATEX for explosive atmospheres category G group II thermal class T4 protection Exd motors according to international standards IEC 60034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, Class F, B3 or B5 format and ATEX certified da Notify body. Suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PQ-L ATEX Backward curved blade centrifugal fans

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint. Connection flanges ISO 6580/EUROVENT 1-2
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • Aerodynamically shaped inlet cone
    • Execution 4 directly coupled and executions 1-9-12 with mono-block support in cast iron with ball bearings, designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard according to EN12499

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PS-L ATEX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint. Connection flanges ISO 6580/EUROVENT 1-2
    • Aerodynamically shaped inlet cone
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • Execution 4 directly coupled and executions 1-9-12 with mono-block support in cast iron with ball bearings, designed for an ideal alignment of the ball bearings and an easy lubrication
    • Pulleys, belts and motor support suitable for the regulation of the belts tension. Belt protection guard according to EN12499
    • Asynchronous three-phase ATEX motors for explosive atmospheres category G group II thermal class T4 protection Exd according to international standards IEC 60034, IEC 60072, IEC60079 and/or 61241, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, Class F, B3 or B5 format and ATEX certified da Notify body. Suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PR-L ATEX Backward curved blade centrifugal fans for clean or slightly dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint. Connection flanges ISO 6580/EUROVENT 1-2.
    • Aerodynamically shaped inlet cone
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • Execution 4 directly coupled and executions 1 – 9 – 12 with mono-block support in cast iron with ball bearings, designed for an ideal alignment of the ball bearings and an easy lubrication. Pulleys, belts and motor support suitable for the regulation of the belts tension. Belt protection guard according to EN12499.
    • Asynchronous three-phase ATEX for explosive atmospheres category G group II thermal class T4 protection Exd motors according to international standards IEC 60034, IEC 60072, IEC60079 and/or 61241, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, Class F, B3 or B5 format and ATEX certified da Notify body. Suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair AL-ATEX Forward curved blade centrifugal fans

    Construction

    • Volute casing in folded steel sheet, protected against atmospheric agent by epoxy paint
    • Single inlet, single width, forward curved impeller (sirocco type), manufactured in galvanized steel sheet from type 200 to 315 and in steel sheet with welded blades epoxy painted from type 355 to 450
    • Brass inlet on models gauge execution IIC and steel sheet with epoxy finish on models IIB
    • Execution 4 (with impeller directly coupled to motor)
    • Standard orientation LG 270°

    MOTOR

    • Asynchronous three-phase motors or singlephase according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/CE, LVD 2006/95/ CE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55/IP 65, class F. Suitable to S1 service (continuous working at constant load).

    Accessories

    • Inlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents
    • Round inlet cone, in steel sheet epoxy coated

    CATALOGUE

    Quick View
  • Dynair DIC-ATEX – DIC-INOX-ATEX Forward curved blade centrifugal fans

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint or in stainless steel AISI304 sheet
    • Single inlet, single gauge, forward curved impeller (sirocco type), in galvanized steel sheet or in stainless steel AISI304
    • Steel sheet inlet with epoxy finish or inox inlet on models IIB. Brass inlet on models with execution IIC
    • Execution 5 (with impeller directly coupled to flanged motor)
    • Motor separated from the conveyed airflow
    • Standard orientation LG270°
    • Inlet connector supplied (disassembled)
    • DIC-ATX and DIC-ATX INOX asynchronous three- phase motors or single-phase according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55, class F, B35 shape. Suitable to S1 service (continuous working at constant load)

    Accessories

    • Motor support in steel or steel sheet
    • Inlet and outlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents

    CATALOGUE

    Quick View
  • Dynair QC ATEX Plate mounted axial fans

    Construction

    • Supporting frame in drawn steel sheet, with wide radius inlet cone. Models 63 and 71 with epoxy finish coat
    • Impeller with airfoil blades in glass reinforced antistatic polyamide and hub in die-cast aluminium alloy, balanced according ISO 1940
    • Execution 5 (direct coupling motor/impeller). Airflow from motor to impeller
    • Inlet protection guard in steel painted rod, manufactured according to norms UNI 12499 and weatherproof
    • Asynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2014/30/UE, LVD 2014/35/UE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55, class F. Suitable to S1 service (continuous working at constant load) accessories
    • Gravity shutter (S)
    • Spacer manufactured in epoxy painted steel sheet (D)
    • Impeller side protection guard manufactured according to UNI ISO 12499 rules and protected against atmospheric agents (R)
    • ATEX service switch

    CATALOGUE

    Quick View