Termékek

  • Dynair Inverter and Line filter

    VSD – Variable Speed Drive.

    • SPWM Control
    • Integrated EMI filter
    • Settable operation functions
    • Interface MODBAS RS485.
    • Upon request DeviceNet, Profi bus, Lon Works, CANopen protocols
    • Wall installation, optional DIN bar

    VFD “EL”: Keypad with incorporated fixed potentiometer.
    VFD “E”: Integrated PLC. Keypad with removable potentiometer, ideal for multiple installations with a unique and remote-manageable programmation (a cable of 5 mt max. length is available upon request). Mounting port for extension card available.

    KATALOG

     

    Quick View
  • PV-L/AT-INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted
    • For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, designed for easy lubrication
    • Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair PS-L/AT-INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • PR-L/AT-INOX Backward curved blade centrifugal fans for clean or slightly dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair RVT Threephase self-transformer speed regulator 2A

    CONSTRUCTION

    • Supply 400V-3Ph-50/60Hz.
    • Nominal current max 2 A.
    • Output voltage 1(90V)-2(140V)-3(180V)-4(230V)-5(400V).
    • Protection IP 54.
    • Pilot light
    • Housing in die-cast aluminium RAL 7001 (grey) with cover in plastic material RAL7035 (light)
    • Weight Kg 7.5

    CATALOGUE

    Quick View
  • Dynair R15 Single-phase electronic speed regulator 1.5 A

    Construction

    • Infinitely variable electronic speed controller by potentiometer
    • New design with cover
    • ON/OFF light switch
    • Suitable for surface and built-in application
    • Ease of connection by the means of removable terminals
    • External trimmer for the adjustment of the fan minimum speed
    • Protection fuse
    • Single-phase 230V – 50/60 Hz
    • Max. load 1.5 A
    • Protection IP42
    • Weight 0,5 Kg
    • Dimensions 110x80x42
    • CE marked

    CATALOGUE

    Quick View
  • Dynair R10 Single-phase electronic speed regulator 1 A

    Construction

    • Infinitely variable electronic speed controller by potentiometer
    • New design with cover
    • ON/OFF light switch
    • Suitable for surface and built-in application
    • Ease of connection by the means of removable terminals
    • External trimmer for the adjustment of the fan minimum speed
    • Protection fuse
    • Single-phase 230V – 50/60 Hz
    • Max. load 1 A
    • Protection IP42
    • Weight 0,5 Kg
    • Dimensions 110x80x42
    • CE marked

    CATALOGUE

    Quick View
  • Dynair JET FANS CC JD LP Axial impulse fans – Low profile shape

    Construction

    • Silencers in galvanized steel sheet inside lined with high performance acoustic insulation material
    • Deflector on outlet side for optimum air discharge and air cleaning of all layers. Supplied as standard
    • Protection guard on inlet side
    • Fixing brackets in galvanized steel sheet for ceiling (or wall) installation. Supplied as standard and pre-assembled
    • Octagonal shaped silencers
    • Housing in electrolytically galvanized steel sheet
    • Hub impeller and airfoil profile blades made in aluminium. Balanced according to ISO 1940 G.6.3. Variable pitch angle in still position
    • Terminal box IP54, resistant to high temperature and supplied as standard
    • Asynchronous three-phase motors 380-420V 50Hz according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE. Motors suitable for DOL (Direct On Line) start. CE marked. Protection IP55, class F or H. Execution 4 (with impeller directly coupled to motor with feet).

    CATALOGUE

    Quick View
  • Dynair Ancillary control systems

    Control panels – CO and gas sensors

    CE 408 – Panel for small systems – from 4 to 8 CO sensors

    • Equipped with 4 inputs and 5 relays expandable upto 8 inputs and 9 relays
    • IP 40

    CE 424 – Panel for medium size systems – from 4 to 24 CO sensors

    • Equipped with 4 inputs and 5 relays expandable up to 24 inputs and 25 relays
    • IP 40

    CE 700 – Panel for large systems up to 200 sensors

    • Equipped with 16 inputs expandable up to 184 for a total of 200 CO sensors
    • Wall or rack versions
    • IP 40

    Industrial gas detectors (single or double gas):
    Replaceable catalytic, electrochemical, pellistor cartridge.
    Suitable for CO, petrol vapours and other gases according to the reference Norm.
    IP65

    CATALOGUE

    Quick View
  • Dynair REIDUCT-C Aeraulic circular ducting EI120

    With REIDUCT-C ducting system it is possible to design highly valuable aeraulic systems ensuring the correct fire division areas, in perfect compliance with the regulations.

    It consists of modular elements of circular  cross-section, available in diameters 200 ÷ 300mm.
    They complete the SVP system for fire-fighting lobbies.
    They are availbel with square section: REIDUCT-Q

    CATALOGUE

    Quick View
  • Dynair REIDUCT-Q Aeraulic square ducting EI120

    With REIDUCT ducting system it is possible to design highly valuable aeraulic systems ensuring the correct fire division areas, in perfect compliance with the regulations.

    Ducts and connectors are made in metal to achieve a perfect connection between the pressurizing unit (fan) and the air intake elements. They ensure a perfect distribution of the air with low pressure losses.They complete the SVP system for fire-fighting lobbies.
    Available with circular section: REIDUCT-C

    CATALOGUE

    Quick View
  • Dynair SVP Fire fighting lobbies

    The pressurization of the lobby can be made in 2 modalities according to the configuration of the lobby:

    1. Pressurization ONLY in case of emergency: this is the case of lobbies in which doors are usually kept opened.

    2. Continuous pressurization of the lobby 24h running: this is the case of lobbies in which doors are usually kept closed.

    CATALOGUE