Dynair CC SHT High efficiency duct axial fans F300/120 – F400
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- High efficiency axial impeller in die-cast aluminium with aerofoil profile blades, totally made. Balanced according ISO 1940. Variable pitch angle in still position
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motor
- Asynchronous three-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F or H, F200, F300 or F400 certified according to the European Directive EN 12101-3. Horizontal axis as standard (other orientations on request)
Accessories
- Extension with inspection door (CCpro)
- Inlet cone (CCbo)
- High tempeeration fl exible joint (CCga-HT)
- Flat protection grid (CCr)
- Support feet (CCst)
- Counter-fl ange (CCf)
- Counter-fl ange with collar (CCfc)
- Cylindrical silencers (CCsa/CCsb)
- Roof terminal (Kit TAV-HT)
- Anti-vibration mounts
<
CATALOGUE
-
Dynair CC-HP High performance ducted axial fan
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- Axial impeller with aerofoil profile blades in glass reinforce polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from motor to impeller
Motorizations:
- CC: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F.
- CC-ATX: asynchronous three-phase motors or single-phase II2G,II2D,II2GD according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification, CE marked, IP55/IP 65, class F.
- All motors suitable to S1 service (continuous working at constant load).
Accessories
- Extension (for long casing version) with inspection porthole (CCpro)
- Flat protection guard (CCr)
- Conic protection guard (CCrc)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts
CATALOGUE
ACCESSORIES
A termék már hozzá lett adva! View Wishlist -
Dynair CC-HT High performance duct axial fans F300/120 – F400
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- High performance axial impeller with aerofoil profile blades, totally made in die-cast aluminium. Balanced according ISO 1940. Variable pitch angle in still position
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motor
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F or H, F200, F300 or F400 certified according to the European Directive EN 12101-3
Accessories
- Extension with inspection door (CCpro)
- Flat protection grid (CCr)
- High temperation flexible joint (CCga-HT)
- Support feet (CCst)
- Inlet cone (CCbo)
- Counter-flange (CCf)
- Counter-flange with collar (CCfc)
- Anti-vibration mounts
CATALOGUE
-
Dynair CC-JC Centrifugal induction fans – Car park ventilation
Construction
- Hub impeller and airfoil prof le blades made in aluminium. Balanced according to ISO 1940
- Housing in electrolytically galvanized steel sheet
- Protection guard on inlet side
- Fixing brackets in galvanized steel sheet for ceiling/ wall installation supplied pre-assembled
- Asynchronous three-phase double polarity motor 380-420V – 50 Hz suitable to work up to a maximum temperature of 40°C (service S1) and 300°C for 120 minutes in case of fire emergency (service S2). CE marked, IP55 protection, Class H. Suitable for continuous running (S1). Execution 5: Impeller directly coupled on the motor shaft.
CATALOGUE
-
Dynair CCB Bifurcated ducted axial fans
Construction
- Stainless steel AISI 304 casing, with airtight motor housing, with fixing flanges manufactured according to ISO 13351
- High performance axial impeller with aerofoil profile blades and hub in diecast aluminium, balanced according ISO 1940. Variable pitch angle
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motorAsynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/34/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable to S1 service (continuous working at constant load).
Accessories
- Flat protection guard (CCr)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts.
CATALOGUE
ACCESSORIES
A termék már hozzá lett adva! View Wishlist -
Dynair CCP Portable duct axial fans
Construction
- Casing in steel sheet and support stand in tubular metal, protected against the atmospheric agents with epoxy paint. Side hand-wheels for the orientation of the throw
- Protection guards in inlet and outlet manufactured according to rules UNI 12499
- Aerofoil profi le impeller with blades in mineral fibres reinforced technopolymer (models 310 to 400) and die cast aluminium alloy (models 450 and 560)
- Execution 5 (with impeller direct coupled on the shaft end) and airflow from motor to impeller
- External rotor motors with built in thermal protection, double speed three-phase and single phase speed-adjustable, all motors with connection box.
CATALOGUE
-
Dynair CCZ Compact and high efficiency ducted axial fans
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- High quality aerofoil profiled impellers in mineral fibres reinforced technopolymer (310 to 400) and diecast aluminum alloy (450 to 560). Blades are directly fixed to the motor external rotor
- Execution 5 (with impeller directly coupled to the motor) and airflow from motor to impeller
- External rotor motors with built-in thermal protection, double speed three-phase and single- phase, speed adjustable. All motors with mounted connection box
Accessories
- Flat protection guard (CCr)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts.
CATALOGUE
ACCESSORIES
-
Dynair DA Direct drive double inlet fans
Construction
- Volute in galvanized steel sheet
- Direct drive double inlet forward curved wheel
- Single-phase and three-phase motor (only 12/9 and 12/12), IP20, class F. Thermal protection in single-phase versions. Particularly suitable for speed regulation (using the suitable speed regulators shown in this catalogue)
Accessories
- Outlet flange
- Fixing feet
CATALOGUE
ACCESSORIES
-
Dynair DA-T Direct drive double inlet fans without motor
The fans of the DA-T series are suitable in plants of ventilation and air conditioning, filtering and heating. They can only handle clean air with temperature range from -20°C to +80°C and to work they require a containing structure (plenum).
The fans must be used within the limits shown in the relevant table.They can only handle clean air up to the maximum temperature of 40°C and to work they require a containing structure (plenum). The fans must be used within the limits shown in the relevant table.
Upon request:
- “CUBIK” version.
CATALOGUE
ACCESSORIES
A termék már hozzá lett adva! View Wishlist -
Dynair DIC AT Forward curved blade centrifugal fans for air temperature up to +150°C
Construction
- Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
- Single inlet, single width forward curved impeller (sirocco type), in galvanized steel sheet
- Execution 5 (with impeller directly coupled to flanged motor)
- Standard orientation LG270°
- Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC 100 T and M with motor shape B14, IP44, class B.
Accessories
- Inlet and outlet protection guard according to UNI 12499 rules and protected against atmospheric agents
- Motor support in steel sheet epoxy painted.
CATALOGUE
A termék már hozzá lett adva! View Wishlist -
Dynair DIC Forward curved blade centrifugal fans
Construction
- Volute casing in steel sheet, protected againstatmospheric agents by epoxy paint
- Single inlet, single width, forward curved impeller (sirocco type), in galvanized steel sheet
- Execution 5 (with impeller directly coupled to flanged motor)
- Standard orientation LG 270°
- Motorization: Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC 100 T and M with motor shape B14, IP44, class B. All motors suitable to S1 service (continuous working at constant load).
Accessories
- Inlet and outlet protection guard according to UNI 10615 rules and protected against atmospheric agents
- Motor support in steel sheet epoxy painted.
CATALOGUE
ACCESSORIES
-
Dynair DIC-ATEX – DIC-INOX-ATEX Forward curved blade centrifugal fans
Construction
- Volute casing in steel sheet, protected against atmospheric agents by epoxy paint or in stainless steel AISI304 sheet
- Single inlet, single gauge, forward curved impeller (sirocco type), in galvanized steel sheet or in stainless steel AISI304
- Steel sheet inlet with epoxy finish or inox inlet on models IIB. Brass inlet on models with execution IIC
- Execution 5 (with impeller directly coupled to flanged motor)
- Motor separated from the conveyed airflow
- Standard orientation LG270°
- Inlet connector supplied (disassembled)
- DIC-ATX and DIC-ATX INOX asynchronous three- phase motors or single-phase according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55, class F, B35 shape. Suitable to S1 service (continuous working at constant load)
Accessories
- Motor support in steel or steel sheet
- Inlet and outlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents
CATALOGUE