Termékek
-
Dynair BOX-T HT Belt driven double inlet box fans F400
Construction
- Dismountable cabinet in galvanized steel sheet. Double inlet impeller with forward curved blades in galvanized steel sheet
- Belt coupling with self aligning supports, outside the airflow. Height adjustable motor support plate for the tensioning of the belt. Belt coupling is protected by a guard in galvanized sheet
- Asynchronous three-phase motor, IP 55 mechanical protection, insulation class F, single or double polarity, suitable for S1 service, mounting type B3, construction according to IEC/EEC
(UNEL MEC) - Arrangement 9: belt coupling with motor placed on the upper panel
- Arrangement 12: belt coupling with motor placed aside on a common basement (only for motors above 7.5kW)
Accessories
- Rainproof cover for outdoor installation
CATALOGUE
-
Dynair SS-BOX Super-silent acoustic cabinet fans
Construction
- Main structure in galvanized steel sheet, inside lined with extra-thick acoustic insulation (50 mm)
- Single-phase electric motor, IP44/IP20, class F, with thermal protection, suitable for speed regulation (using the suitable speed regulators shown in this catalogue)
- Backward bladed impeller with high efficiency (mod.125-160-200-250)
- Double inlet forward bladed fan (mod. 315-355-400-450)
Accessories
- Speed regulators
- Shutters
- Protection guards
- Collars for fixing to the duct
- Silencers
CATALOGUE
ACCESSORIES
-
Dynair ZOO Belt driven axial fans
Construction
- Belt-driven fans
- Airflow outside the motor
- Housing manufactured in galvanized steel sheet
- Impeller blades made of stainless steel AISI 304 with aluminium hub
- Asynchronous three phase motor ball bearing motors 230/400V – 50Hz suitable for continuous running
- Protection grade IP54, Class F
CATALOGUE
-
Dynair CCZ Compact and high efficiency ducted axial fans
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- High quality aerofoil profiled impellers in mineral fibres reinforced technopolymer (310 to 400) and diecast aluminum alloy (450 to 560). Blades are directly fixed to the motor external rotor
- Execution 5 (with impeller directly coupled to the motor) and airflow from motor to impeller
- External rotor motors with built-in thermal protection, double speed three-phase and single- phase, speed adjustable. All motors with mounted connection box
Accessories
- Flat protection guard (CCr)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts.
CATALOGUE
ACCESSORIES
A termék már hozzá lett adva! View Wishlist -
Dynair CC-HP High performance ducted axial fan
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- Axial impeller with aerofoil profile blades in glass reinforce polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from motor to impeller
Motorizations:
- CC: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F.
- CC-ATX: asynchronous three-phase motors or single-phase II2G,II2D,II2GD according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification, CE marked, IP55/IP 65, class F.
- All motors suitable to S1 service (continuous working at constant load).
Accessories
- Extension (for long casing version) with inspection porthole (CCpro)
- Flat protection guard (CCr)
- Conic protection guard (CCrc)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts
CATALOGUE
ACCESSORIES
-
Dynair FCV 2V Double speed centrifugal roof fans – Vertical discharge
Construction
- Base frame in galvanized steel sheet
- Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
- Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
- Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
- Upper cover in ABS, with appropriate slots for motor cooling
- Outer deflector in ABS
Accessories
- Backdraught gravity shutter (TS)
- Silencer (GR)
- Support base for wawed roof coverings (BA)
- Inlet Protection Guard (RA)
- Service switch
- Support base/Silenced reduction (PB)
CATALOGUE
ACCESSORIES
-
Dynair FC 2V Double speed centrifugal roof fans – Horinzontal discharge
Construction
- Base frame in galvanized steel sheet
- Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
- Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
- Asynchronous and double polarity three-phase motor manufactured according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP55 Class F.
- Upper cover in techno-polymer, with appropriate slots for motor cooling
- Outer deflector in techno-polymer.
Accessories
- Backdraught gravity shutter (TS)
- Silencers (GR)
- Counterbase (CB)
- Support base for wawed roof coverings (BA)
- Inlet side Guard (RA)
- Service switch
- Self transformer speed regulator
- Delta/start switch
- Support base/Silenced reduction (PB)
CATALOGUE
ACCESSORIES
-
Dynair DA-T Direct drive double inlet fans without motor
The fans of the DA-T series are suitable in plants of ventilation and air conditioning, filtering and heating. They can only handle clean air with temperature range from -20°C to +80°C and to work they require a containing structure (plenum).
The fans must be used within the limits shown in the relevant table.They can only handle clean air up to the maximum temperature of 40°C and to work they require a containing structure (plenum). The fans must be used within the limits shown in the relevant table.
Upon request:
- “CUBIK” version.
CATALOGUE
ACCESSORIES
-
Dynair MULTIBOX Centralized single flow extract ventilation
Construction
- Casing in galvanised steel sheet.
- Backward blade impeller for high efficiency and low noise level.
- Easy access to motor and impeller for inspection.
- Compliance with EN 60335-2-80, B.T. 2014/35/UE, EMC 2014/30/UE
- IPX4
Accessories
- RLS 1 WR Remote control for the manual selection of the ventilation level (min/Intermediate/high). Suitable for Microbox EC.
- RLS 3V Remote control for the manual selection of the ventilation level (min/Intermediate/high) and On/Off switch. Suitable for Microvox 3V AC.
CATALOGUE
-
Dynair MICROBOX Centralized single flow extract ventilation
Construction
- Casing in galvanised steel sheet inside lined with acoustic insulation.
- Backward blade impeller for high efficiency and low noise level.
- Wall/ceiling fixing kit for an easy and quick installation (Maico Italia patent).
- Easy access to motor and impeller for inspection.
- Supplied with plastic sealing rings for the spigots.
- Compliance with EN 60335-2-80, B.T. 2014/35/UE, EMC 2014/30/UE
- IPX4
Accessories
- RLS 1 WR Remote control for the manual selection of the ventilation level (min / Intermediate / high). Suitable for Microbox EC.
- RLS 3V Remote control for the manual selection of the ventilation level (min / Intermediate / high) and On/Off switch. Suitable for Microvox 3V AC.
CATALOGUE
-
Dynair REC SanAir Decentralized HRU
The series is available in 3 models:
REC SanAir WALL
Installation on all kind of perimetric wall.
Unique model for horizontal or vertical installation.
Easy installation: 2 holes of ø 100 mm are sufficient.REC SanAir IN WALL
Installation on any kind of perimetrical wall.
Built-in horizontal or vertical installation.REC SanAir WINDOW
Installation on all kind of window frame with dimensions
up to 180 mm of width and 3000 mm
of length.CATALOGUE
A termék már hozzá lett adva! View Wishlist -
Dynair REC DUO 100 – Decentralized Heat Recovery Unit
Construction
- Stylish and ultra-slim front cover. Very compact dimensions.
- Ceramic type high efficiency exchanger.
- Provided with filters G3 class both in intake and in extract, easily removable and washable.
- Free-cooling and Antifreeze functions.
- EC brushless motor.
- Comply with EN 60335-2-80, LVD 2014/35/UE, EMC 2014/30/UE.
- IPX4
- CE marked
Accessories
- RLS remote controller (on/off switch and boost actication) suitable for versions Rec Duo 100 and Rec Duo 100 MHY
CATALOGUE
A termék már hozzá lett adva! View Wishlist