Termékek

  • Dynair BOX-T HT Belt driven double inlet box fans F400

    Construction

    • Dismountable cabinet in galvanized steel sheet. Double inlet impeller with forward curved blades in galvanized steel sheet
    • Belt coupling with self aligning supports, outside the airflow. Height adjustable motor support plate for the tensioning of the belt. Belt coupling is protected by a guard in galvanized sheet
    • Asynchronous three-phase motor, IP 55 mechanical protection, insulation class F, single or double polarity, suitable for S1 service, mounting type B3, construction according to IEC/EEC
      (UNEL MEC)
    • Arrangement 9: belt coupling with motor placed on the upper panel
    • Arrangement 12: belt coupling with motor placed aside on a common basement (only for motors above 7.5kW)

    Accessories

    • Rainproof cover for outdoor installation

    CATALOGUE

    Quick View
  • Dynair SS-BOX Super-silent acoustic cabinet fans

    Construction

    • Main structure in galvanized steel sheet, inside lined with extra-thick acoustic insulation (50 mm)
    • Single-phase electric motor, IP44/IP20, class F, with thermal protection, suitable for speed regulation (using the suitable speed regulators shown in this catalogue)
    • Backward bladed impeller with high efficiency (mod.125-160-200-250)
    • Double inlet forward bladed fan (mod. 315-355-400-450)

    Accessories

    • Speed regulators
    • Shutters
    • Protection guards
    • Collars for fixing to the duct
    • Silencers

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair ZOO Belt driven axial fans

    Construction

    • Belt-driven fans
    • Airflow outside the motor
    • Housing manufactured in galvanized steel sheet
    • Impeller blades made of stainless steel AISI 304 with aluminium hub
    • Asynchronous three phase motor ball bearing motors 230/400V – 50Hz suitable for continuous running
    • Protection grade IP54, Class F

    CATALOGUE

    Quick View
  • Dynair CCZ Compact and high efficiency ducted axial fans

    Construction

    • Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
    • High quality aerofoil profiled impellers in mineral fibres reinforced technopolymer (310 to 400) and diecast aluminum alloy (450 to 560). Blades are directly fixed to the motor external rotor
    • Execution 5 (with impeller directly coupled to the motor) and airflow from motor to impeller
    • External rotor motors with built-in thermal protection, double speed three-phase and single- phase, speed adjustable. All motors with mounted connection box

    Accessories

    • Flat protection guard (CCr)
    • Flexible connectors (CCga)
    • Support feet (CCst)
    • Inlet/outlet bell mouth (CCbo)
    • Silencers, with and without pod, in three lengths (CCsa and CCsb)
    • Counter flange (Ccf)
    • Counter flange with collar (CCfc)
    • Anti-vibration mounts.

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair CC-HP High performance ducted axial fan

    Construction

    • Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
    • Axial impeller with aerofoil profile blades in glass reinforce polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
    • Execution 4 (with impeller directly coupled to motor with feet) and airflow from motor to impeller

    Motorizations:

    • CC: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F.
    • CC-ATX: asynchronous three-phase motors or single-phase II2G,II2D,II2GD according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification, CE marked, IP55/IP 65, class F.
    • All motors suitable to S1 service (continuous working at constant load).

    Accessories

    • Extension (for long casing version) with inspection porthole (CCpro)
    • Flat protection guard (CCr)
    • Conic protection guard (CCrc)
    • Flexible connectors (CCga)
    • Support feet (CCst)
    • Inlet/outlet bell mouth (CCbo)
    • Silencers, with and without pod, in three lengths (CCsa and CCsb)
    • Counter flange (Ccf)
    • Counter flange with collar (CCfc)
    • Anti-vibration mounts

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FCV 2V Double speed centrifugal roof fans – Vertical discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
    • Upper cover in ABS, with appropriate slots for motor cooling
    • Outer deflector in ABS

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FC 2V Double speed centrifugal roof fans – Horinzontal discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous and double polarity three-phase motor manufactured according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP55 Class F.
    • Upper cover in techno-polymer, with appropriate slots for motor cooling
    • Outer deflector   in techno-polymer.

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencers (GR)
    • Counterbase (CB)
    • Support base for wawed roof coverings (BA)
    • Inlet side Guard (RA)
    • Service switch
    • Self transformer speed regulator
    • Delta/start switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    View Wishlist
    Quick View
  • Dynair DA-T Direct drive double inlet fans without motor

    The fans of the DA-T series are suitable in plants of ventilation and air conditioning, filtering and heating. They can only handle clean air with temperature range from -20°C to +80°C and to work they require a containing structure (plenum).

    The fans must be used within the limits shown in the relevant table.They can only handle clean air up to the maximum temperature of 40°C and to work they require a containing structure (plenum). The fans must be used within the limits shown in the relevant table.

    Upon request:

    • “CUBIK” version.

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair MULTIBOX Centralized single flow extract ventilation

    Construction

    • Casing in galvanised steel sheet.
    • Backward blade impeller for high efficiency and low noise level.
    • Easy access to motor and impeller for inspection.
    • Compliance with EN 60335-2-80, B.T. 2014/35/UE, EMC 2014/30/UE
    • IPX4

    Accessories

    • RLS 1 WR Remote control for the manual selection of the ventilation level (min/Intermediate/high). Suitable for Microbox EC.
    • RLS 3V Remote control for the manual selection of the ventilation level (min/Intermediate/high) and On/Off switch. Suitable for Microvox 3V AC.

    CATALOGUE

    Quick View
  • Dynair MICROBOX Centralized single flow extract ventilation

    Construction

    • Casing in galvanised steel sheet inside lined with acoustic insulation.
    • Backward blade impeller for high efficiency and low noise level.
    • Wall/ceiling fixing kit for an easy and quick installation (Maico Italia patent).
    • Easy access to motor and impeller for inspection.
    • Supplied with plastic sealing rings for the spigots.
    • Compliance with EN 60335-2-80, B.T. 2014/35/UE, EMC 2014/30/UE
    • IPX4

    Accessories

    • RLS 1 WR Remote control for the manual selection of the ventilation level (min / Intermediate / high). Suitable for Microbox EC.
    • RLS 3V Remote control for the manual selection of the ventilation level (min / Intermediate / high) and On/Off switch. Suitable for Microvox 3V AC.

    CATALOGUE

    View Wishlist
    Quick View
  • Dynair REC SanAir Decentralized HRU

    The series is available in 3 models:

     

    REC SanAir WALL
    Installation on all kind of perimetric wall.
    Unique model for horizontal or vertical installation.
    Easy installation: 2 holes of ø 100 mm are sufficient.

    REC SanAir IN WALL
    Installation on any kind of perimetrical wall.
    Built-in horizontal or vertical installation.

    REC SanAir WINDOW
    Installation on all kind of window frame with dimensions
    up to 180 mm of width and 3000 mm
    of length.

    CATALOGUE

    Quick View
  • Dynair REC DUO 100 – Decentralized Heat Recovery Unit

    Construction

    • Stylish and ultra-slim front cover. Very compact dimensions.
    • Ceramic type high efficiency exchanger.
    • Provided with filters G3 class both in intake and in extract, easily removable and washable.
    • Free-cooling and Antifreeze functions.
    • EC brushless motor.
    • Comply with EN 60335-2-80, LVD 2014/35/UE, EMC 2014/30/UE.
    • IPX4
    • CE marked

    Accessories

    • RLS remote controller (on/off switch and boost actication) suitable for versions Rec Duo 100 and Rec Duo 100 MHY

    CATALOGUE

    Quick View