Termékek
-
Dynair CCP Portable duct axial fans
Construction
- Casing in steel sheet and support stand in tubular metal, protected against the atmospheric agents with epoxy paint. Side hand-wheels for the orientation of the throw
- Protection guards in inlet and outlet manufactured according to rules UNI 12499
- Aerofoil profi le impeller with blades in mineral fibres reinforced technopolymer (models 310 to 400) and die cast aluminium alloy (models 450 and 560)
- Execution 5 (with impeller direct coupled on the shaft end) and airflow from motor to impeller
- External rotor motors with built in thermal protection, double speed three-phase and single phase speed-adjustable, all motors with connection box.
CATALOGUE
-
Dynair CCB Bifurcated ducted axial fans
Construction
- Stainless steel AISI 304 casing, with airtight motor housing, with fixing flanges manufactured according to ISO 13351
- High performance axial impeller with aerofoil profile blades and hub in diecast aluminium, balanced according ISO 1940. Variable pitch angle
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motorAsynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/34/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable to S1 service (continuous working at constant load).
Accessories
- Flat protection guard (CCr)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts.
CATALOGUE
ACCESSORIES
-
Dynair CC-JC Centrifugal induction fans – Car park ventilation
Construction
- Hub impeller and airfoil prof le blades made in aluminium. Balanced according to ISO 1940
- Housing in electrolytically galvanized steel sheet
- Protection guard on inlet side
- Fixing brackets in galvanized steel sheet for ceiling/ wall installation supplied pre-assembled
- Asynchronous three-phase double polarity motor 380-420V – 50 Hz suitable to work up to a maximum temperature of 40°C (service S1) and 300°C for 120 minutes in case of fire emergency (service S2). CE marked, IP55 protection, Class H. Suitable for continuous running (S1). Execution 5: Impeller directly coupled on the motor shaft.
CATALOGUE
-
Dynair CC-HT High performance duct axial fans F300/120 – F400
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- High performance axial impeller with aerofoil profile blades, totally made in die-cast aluminium. Balanced according ISO 1940. Variable pitch angle in still position
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motor
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F or H, F200, F300 or F400 certified according to the European Directive EN 12101-3
Accessories
- Extension with inspection door (CCpro)
- Flat protection grid (CCr)
- High temperation flexible joint (CCga-HT)
- Support feet (CCst)
- Inlet cone (CCbo)
- Counter-flange (CCf)
- Counter-flange with collar (CCfc)
- Anti-vibration mounts
CATALOGUE
A termék már hozzá lett adva! View Wishlist -
Dynair CC-HP High performance ducted axial fan
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- Axial impeller with aerofoil profile blades in glass reinforce polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from motor to impeller
Motorizations:
- CC: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F.
- CC-ATX: asynchronous three-phase motors or single-phase II2G,II2D,II2GD according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification, CE marked, IP55/IP 65, class F.
- All motors suitable to S1 service (continuous working at constant load).
Accessories
- Extension (for long casing version) with inspection porthole (CCpro)
- Flat protection guard (CCr)
- Conic protection guard (CCrc)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts
CATALOGUE
ACCESSORIES
-
Dynair CC SHT High efficiency duct axial fans F300/120 – F400
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- High efficiency axial impeller in die-cast aluminium with aerofoil profile blades, totally made. Balanced according ISO 1940. Variable pitch angle in still position
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motor
- Asynchronous three-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F or H, F200, F300 or F400 certified according to the European Directive EN 12101-3. Horizontal axis as standard (other orientations on request)
Accessories
- Extension with inspection door (CCpro)
- Inlet cone (CCbo)
- High tempeeration fl exible joint (CCga-HT)
- Flat protection grid (CCr)
- Support feet (CCst)
- Counter-fl ange (CCf)
- Counter-fl ange with collar (CCfc)
- Cylindrical silencers (CCsa/CCsb)
- Roof terminal (Kit TAV-HT)
- Anti-vibration mounts
<
CATALOGUE
-
Dynair CC Ducted axial fan
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- Axial impeller with aerofoil profile blades in glass reinforce polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
- Execution 4 (with impeller directly coupled to motor with feet) and airflow from motor to impeller
Motorizations:
- CC: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F.
- CC-ATX: asynchronous three-phase motors or single-phase II2G,II2D,II2GD according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification, CE marked, IP55/IP 65, class F.
- All motors suitable to S1 service (continuous working at constant load).
Accessories
- Extension (for long casing version) with inspection porthole (CCpro)
- Flat protection guard (CCr)
- Conic protection guard (CCrc)
- Flexible connectors (CCga)
- Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts
KATALÓGUS
KIEGÉSZÍTŐK
-
Dynair CC ATEX Ducted axial fan
Construction
- Short casing in steel sheet, with fixing flanges manufactured according to UNI ISO 6580-EUROVENT standard. Protected against atmospheric agents by epoxy paint
- Axial impeller with aerofoil profile blades in glass reinforce antistat polyamide and die-cast aluminium hub, balanced according ISO 1940. Variable pitch angle in still position with setting means
- Impeller and sparkproof band in alluminium, according to the type of construction
- Execution 4 (with impeller directly coupled to motor) and airflow from motor to impeller
- Asynchronous three-phase motors or singlephase according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2014/30/UE, LVD 2014/35/UE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55, class F. Suitable to S1 service (continuous working at constant load)
Accessories
- Extension (for long casing version) with inspection porthole (CCpro)
- Flat protection guard (CCr)
- Conic protection guard (CCrc)
- Flexible connectors (CCga)Support feet (CCst)
- Inlet/outlet bell mouth (CCbo)
- Silencers, with and without pod, in three lengths (CCsa and CCsb)
- Counter flange (Ccf)
- Counter flange with collar (CCfc)
- Anti-vibration mounts
- External ATEX terminal box
- ATEX service switch
CATALOGUE
-
Dynair BOX-T HT Belt driven double inlet box fans F400
Construction
- Dismountable cabinet in galvanized steel sheet. Double inlet impeller with forward curved blades in galvanized steel sheet
- Belt coupling with self aligning supports, outside the airflow. Height adjustable motor support plate for the tensioning of the belt. Belt coupling is protected by a guard in galvanized sheet
- Asynchronous three-phase motor, IP 55 mechanical protection, insulation class F, single or double polarity, suitable for S1 service, mounting type B3, construction according to IEC/EEC
(UNEL MEC) - Arrangement 9: belt coupling with motor placed on the upper panel
- Arrangement 12: belt coupling with motor placed aside on a common basement (only for motors above 7.5kW)
Accessories
- Rainproof cover for outdoor installation
CATALOGUE
-
Dynair Box-T Belt driven double inlet box fans
Construction
- Frame in extruded aluminium profiles and removable panels in galvanized steel sheet
- Plenum lining of the with self-extinguishing techno-polymer material
- Double inlet centrifugal fan with forward curved blades, driven by trapezoidal belts and adjustable pulleys. Fan and motor supported by single base frame and isolated from the main structure by anti-vibration mounts and flexible joint on the outlet
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F. Suitable for S1 service (continuous working at constant load).
Accessories
- Weatherproof protection cover
- Support feet
- Outlet terminal with guard
- Setting shutter
- Setting shutter with filtering section (standard version with filter in polyester with efficiency 90.1%, class EU4).
CATALOGUE
-
Dynair Box-D Direct drive double inlet box fans
Construction
- Frame in extruded aluminium profile; removable panels in galvanized steel sheet; all this brings to an excellent aesthetic impact. Weatherproof cover in galvanized steel sheet
- The blower is fitted using suitable support feet and is completely isolated from the casing by anti-vibration mounts and gaskets
- Acoustic lining in self-extinguishing technopolymer
- Double inlet blower, forward curved, with direct drive built-in asynchronous motor, singlephase or three-phase, IP20, class F, particularly suitable for speed regulation (using the suitable speed regulators shown in this catalogue)
- Weatherproof upper cover with suitable holes for lifting hooks
Accessories
- Rainproof outlet with guard
- Support feet
- Filtering section (standard version with filter in polyester with efficiency 90.1%, class EU4).
CATALOGUE
ACCESSORIES
-
Dynair Box-CA Active carbon filtering units
Construction
- Frame in extruded aluminium profi les and removable double skin panels in galvanized steel sheet
- Lining of the plenum with self-extinguishing techno-polymer material
- Double inlet centrifugal fan with forward curved blades, driven by trapezoidal belts and adjustable pulleys. Fan and motor supported by single base frame and isolated from the main structure by anti-vibration mounts and flexible joint on the outlet
- Filtering battery composed by wavy polyester pre-filter (class G3), pocket filter (class F7) and activated charcoal filter in cartridges
- Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable for S1 service (continuous working at constant load)
Accessories
- Weatherproof cover
CATALOGUE
A termék már hozzá lett adva! View Wishlist -
Dynair AXC – LINE METAL Round duct centrifugal in-line fans
Construction
- Casing in steel sheet, protected against atmospheric agents by epoxy paint
- Single-phase electric ball-bearing motor with non-self resetting thermal cut-out, particularly suitable for speed regulation
- Backward curved centrifugal impeller with high efficiency and low noise level. Statically and dynamically balanced according to ISO 1940
- Down stream guide vanes, for improved efficiency
- External electric connections enclosed in a terminal box in self-extinguishing technopolymer, with IP54 protection
- Comply with EN 60335-2-80, B.T. 2006/95/ CE, EMC 2004/108/CE
Accessories
- Speed regulators
- Back-draught shutters
- Protection guard
- Collars for fixing to the duct
- Silencers
CATALOGUE
ACCESSORIES
A termék már hozzá lett adva! View Wishlist -
Dynair AxB Super-silent acoustic cabinet fans
Construction
- Casing in galvanized steel sheet with fixing flanges of standardized dimensions
- Single-phase and three-phase electric external rotor motor, IP44, class B/F, with internal thermal protection, suitable for speed control (using the suitable speed regulators shown in this catalogue)
- Backward curved impeller for models 4×2, 5×2,5 and 5×3, forward curved impeller for models 6×3, 6×35 and 7×4
- External electric connection box, in a self-extinguishing techno-polymeric box, resistant to atmospheric agents with IP55 protection.
Accessories
- Speed regulators
- Silencers
- Flexible connections
CATALOGUE
ACCESSORIES
-
Dynair Ancillary control systems
Control panels – CO and gas sensors
CE 408 – Panel for small systems – from 4 to 8 CO sensors
- Equipped with 4 inputs and 5 relays expandable upto 8 inputs and 9 relays
- IP 40
CE 424 – Panel for medium size systems – from 4 to 24 CO sensors
- Equipped with 4 inputs and 5 relays expandable up to 24 inputs and 25 relays
- IP 40
CE 700 – Panel for large systems up to 200 sensors
- Equipped with 16 inputs expandable up to 184 for a total of 200 CO sensors
- Wall or rack versions
- IP 40
Industrial gas detectors (single or double gas):
Replaceable catalytic, electrochemical, pellistor cartridge.
Suitable for CO, petrol vapours and other gases according to the reference Norm.
IP65CATALOGUE
-
Dynair AL-ATEX Forward curved blade centrifugal fans
Construction
- Volute casing in folded steel sheet, protected against atmospheric agent by epoxy paint
- Single inlet, single width, forward curved impeller (sirocco type), manufactured in galvanized steel sheet from type 200 to 315 and in steel sheet with welded blades epoxy painted from type 355 to 450
- Brass inlet on models gauge execution IIC and steel sheet with epoxy finish on models IIB
- Execution 4 (with impeller directly coupled to motor)
- Standard orientation LG 270°
MOTOR
- Asynchronous three-phase motors or singlephase according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/CE, LVD 2006/95/ CE, with Atex certification for explosive atmospheres category G group II thermal class T4 protection Exd, CE marked, IP55/IP 65, class F. Suitable to S1 service (continuous working at constant load).
Accessories
- Inlet protection guard manufactured according to UNI 12499 norm and protected against the atmospheric agents
- Round inlet cone, in steel sheet epoxy coated
CATALOGUE
-
Dynair AL Forward curved blade centrifugal fans
Construction
- Volute casing in folded steel sheet, protected against atmospheric agent by epoxy paint
- Single inlet, single width, forward curved impeller (sirocco type), manufactured in galvanized steel sheet from type 200 to 315 and in steel sheet with welded blades epoxy painted from type 355 to 450
- Execution 4 (with impeller directly coupled to motor with feet)
- Standard orientation LG 270°
Motorizations:
- AL: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/uE, LVD 2014/35/UE, CE marked, IP 55, class F
- AL-ATX: asynchronous three-phase motors or single-phase II2G,II2D,II2GD according to international standards IEC 60034, IEC 60072, IEC 60079 and/or IEC61241, EMC 2004/108/ CE, LVD 2006/95/CE, with Atex certification, CE marked, IP55/IP 65, class F
- All motors suitable to S1 service (continuous working at constant load)
Accessories
- Inlet protection guard manufactured according to UNI 10615 norm and protected against the atmospheric agents
- Round inlet cone, in steel sheet epoxy coated.
CATALOGUE
ACCESSORIES
-
Dynair AC-A and AC-B Ring axial fans
The fans of the AC series are suitable for the ventilation in residential, commercial and industrial buildings in which are requested relevant air deliveries without canalization.
They are also suitable as OEM in a wide variety of applications. With the addition of a suitable wall mounting square frame adaptor, the AC fans (from size 800 to 1250) can be converted in a wall mounted fan (like QC range).
The series includes 2 versions: AC/A and AC/B, with impeller diameter from 300 a 1250 mm and different motor polarity. The AC-A model has a shaped cone in the inlet side, while for the AC/B the shaped cone is present also on the outlet. They are designed for clean air in the temperature range -10°C 50°C.
The optimized inlet cone reduces noise level and increases the efficiency.Upon request:
- Impeller with airfoil blades in die-cast aluminium alloy
- Airflow from impeller to motor (only AC/B)
CATALOGUE
ACCESSORIES