  • Dynair PS-L/INOX Backward curved blade centrifugal fans for dusty air

    Construction

    • Volute casing in steel sheet , protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, , designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load)

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    View Wishlist
    Quick View
  • Dynair PR-L/INOX Backward curved blade centrifugal fans for clean or slightly dusty air

    Construction

    • Volute casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Aerodynamically shaped inlet cone in steel sheet, protected against atmospheric agents by epoxy paint
    • Single inlet backward curved wheel with high efficiency, manufactured in steel sheet and epoxy painted. For high rotational speed, versions in class 3 are foreseen
    • For execution 1 – 9 – 12: mono-block support in cast iron with ball bearings, designed for easy lubrication. Pulleys, belts and motor support. Belt protection guard
    • Asynchronous three-phase motors according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/CE, CE marked, IP 55, class F, suitable to S1 service (continuous working at constant load).

    Accessories

    • Condensation drain hole (TS)
    • Inspection door (PI)
    • Inlet counter-flange (CFA)
    • Outlet counter-flange (CFP)
    • Inlet protection guard (RA)
    • Outlet protection guard (RP)
    • Inlet flexible connector (GA)
    • Outlet flexible connector (GP)
    • Inlet vane control
    • Outlet setting shutter
    • Anti-vibration mounts

    CATALOGUE

    Quick View
  • Dynair CCB Bifurcated ducted axial fans

    Construction

    • Stainless steel AISI 304 casing, with airtight motor housing, with fixing flanges manufactured according to ISO 13351
    • High performance axial impeller with aerofoil profile blades and hub in diecast aluminium, balanced according ISO 1940. Variable pitch angle
    • Execution 4 (with impeller directly coupled to motor with feet) and airflow from impeller to motorAsynchronous three-phase or single-phase motors according to international standards IEC 60034, IEC 60072, EMC 2014/34/UE, LVD 2014/35/UE, CE marked, IP 55, class F. Suitable to S1 service (continuous working at constant load).

    Accessories

    • Flat protection guard (CCr)
    • Flexible connectors (CCga)
    • Support feet (CCst)
    • Inlet/outlet bell mouth (CCbo)
    • Silencers, with and without pod, in three lengths (CCsa and CCsb)
    • Counter flange (Ccf)
    • Counter flange with collar (CCfc)
    • Anti-vibration mounts.

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair DIC-INOX Centrifugal fans in stainless steel

    Construction

    • Volute in stainless steel AISI304 sheet
    • Single inlet forward bladed impeller (sirocco), in stainless steel AISI304
    • Execution 5 (with impeller directly coupled to flanged motor)
    • Standard orientation LG270°
    • Motorizations: asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B35 shape. DIC-INOX 100 T and M with motor shape B14, IP44, class B.

    Accessories

    • Inlet and outlet protection guard according to UNI 12499 norm
    • Motor support in steel sheet protected against atmospheric agents by epoxy paint

    CATALOGUE

    ACCESSORIES

    View Wishlist
    Quick View
  • Dynair PR-AC Centrifugal fans in plastic material

    Construction

    • Volute in polyethylene (PE)
    • Single inlet impeller, in Polypropylene (PP), with backward curved blades and aluminium hub (protected from the fluid)
    • Motor support in epoxy painted steel sheet
    • Asynchronous three-phase or single-phase motors according to international standards IEC 600034, IEC 60072, EMC 2014/30/UE, LVD 2014/35/UE, CE marked, IP 55, class F, B3 or B5 shape. Suitable to a S1 service (continuous working to constant load)

    Accessories

    • Inlet protection guard according to UNI 10615
    • Anti-vibration joint in PVC for inlet and outlet sides
    • Gravity shutter
    • Manual setting shutter

    CATALOGUE

    View Wishlist
    Quick View
  • Dynair TAV Vertical discharge axial conveyors

    Construction

    • Outer conveyor with epoxy painted steel sheet base and with vertical panels in galvanized steel sheet
    • Double wing aluminium gravity shutters, acoustically lined
    • Coupling plate to the fan in epoxy painted steel sheet
    • Weatherproof outlet protection guard according to norm UNI 10615

    Accessories

    TAV conveyors are suitable to be installed with CC range accessories:

    • Long casing extension (CCpro)
    • Intel/Outlet cone (CCbo)
    • Flexible connections (CCga)
    • Protection guards (CCr/CCrc)
    • Flat or collar fl anges (CCf/CCfc)
    • Silencers (CCsa/CCsb)
    • External terminal box (mounted on fan casing)

    CATALOGUE

    Quick View
  • Dynair FCV Single speed centrifugal roof fans – Vertical discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F
    • Upper cover in ABS, with appropriate slots for motor cooling
    • Outer deflector in ABS

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair REV Centrifugal roof fans with external rotor motor – Vertical discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet (mod. 200 in plastic), with high efficiency and low noise level
    • Outer deflector in ABS
    • External rotor motor, three-phase or single phase, IP 44/B 200-250, IP 44/F 310-400, tropycalized with integral thermal protection

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencers (GR)
    • Counter base to be walled up (CB)
    • Support base for corrugated roof coverings (BA)
    • Inlet side Guard (RA)
    • Service switch
    • Speed regulator
    • Delta/start switch
    • Support base/Silenced reduction (PB). Not available for size 200

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair FC Single speed centrifugal roof fans – Horizontal discharge

    Construction

    • Base frame in galvanized steel sheet.
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997.
    • Backward curved wheel in galvanized steel sheet, with high efficiency and low noise level, statically and dynamically balanced according ISO 1940.
    • Asynchronous three-phase motor or single-phase motor manufactured according to international standards IEC 600034, IEC 60072, EMC 2004/108/CE, LVD 2006/95/ CE, CE marked, IP 55, class F.
    • Upper cover in ABS, with appropriate slots for motor cooling.
    • Outer deflector (FCV) in ABS

     

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencer (GR)
    • Support base for wawed roof coverings (BA)
    • Inlet Protection Guard (RA)
    • Service switch
    • Support base/Silenced reduction (PB)

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair REA Centrifugal roof fans with external rotor motor – Horizontal discharge

    Construction

    • Base frame in galvanized steel sheet
    • Protection guard in drawn steel rod protected against the atmospheric agents, manufactured according to UNI 10615:1997
    • Backward curved wheel in galvanized steel sheet (mod. 200 in plastic), with high efficiency and low noise level
    • Upper cover in aluminium
    • External rotor motor, three-phase or single phase, IP 44/B 200-250, IP 44/F 310-400, tropycalized with integral thermal protection.

    Accessories

    • Backdraught gravity shutter (TS)
    • Silencers (GR)
    • Counter base to be walled up (CB)
    • Support base for corrugated roof coverings (BA)
    • Inlet side Guard (RA)
    • Service switch
    • Speed regulator
    • Delta/start switch
    • Support base/Silenced reduction (PB). Not available for size 200

    CATALOGUE

    ACCESSORIES

    Quick View
  • Dynair AxB Super-silent acoustic cabinet fans

    Construction

    • Casing in galvanized steel sheet with fixing flanges of standardized dimensions
    • Single-phase and three-phase electric external rotor motor, IP44, class B/F, with internal thermal protection, suitable for speed control (using the suitable speed regulators shown in this catalogue)
    • Backward curved impeller for models 4×2, 5×2,5 and 5×3, forward curved impeller for models 6×3, 6×35 and 7×4
    • External electric connection box, in a self-extinguishing techno-polymeric box, resistant to atmospheric agents with IP55 protection.

    Accessories

    • Speed regulators
    • Silencers
    • Flexible connections

    CATALOGUE

    ACCESSORIES

    View Wishlist
    Quick View
  • Dynair AXC – LINE METAL Round duct centrifugal in-line fans

    Construction

    • Casing in steel sheet, protected against atmospheric agents by epoxy paint
    • Single-phase electric ball-bearing motor with non-self resetting thermal cut-out, particularly suitable for speed regulation
    • Backward curved centrifugal impeller with high efficiency and low noise level. Statically and dynamically balanced according to ISO 1940
    • Down stream guide vanes, for improved efficiency
    • External electric connections enclosed in a terminal box in self-extinguishing technopolymer, with IP54 protection
    • Comply with EN 60335-2-80, B.T. 2006/95/ CE, EMC 2004/108/CE

    Accessories

    • Speed regulators
    • Back-draught shutters
    • Protection guard
    • Collars for fixing to the duct
    • Silencers

    CATALOGUE

    ACCESSORIES

    Quick View